Processing Orders

Processing Orders

This section outlines step-by-step procedures to process orders in Adaptiv | Cloud Portal.

 

Submitting orders

The order entry form is divided into three parts for easy assimilation of information. The order details are important to configure the Adaptiv | Edge as well as for the post-install maintenance.

Before you begin

  • Make sure that you have gathered all the technical information and customer requirements.
  • Identify the Internet link to be chosen as the primary link and assess the requirement to enable Failover. 
  • It is advisable to enter all required information at the time of order entry. Requesting additional configurations at the time of install might result in a lengthy installation process.
  • For any non-standard configurations requested by the customers, get in touch with the Support Engineers at Adaptiv Networks, and obtain their guidance.
  • Check if the installation site address and shipping address are correct.
  • The information about the underlay links is crucial for the seamless processing of orders. Encourage customers to provide accurate details of the links.
  • Ensure that the required customer account exists in the Portal and that the person entering orders for that customer has access to the account.
  • Partner admin must have the appropriate user permissions to submit Adaptiv My Connect orders, which can be assigned from Admin > Users > User Permissions section. Adaptiv My Connect order provisioning is currently limited to customers with new or existing SD-WAN networks. New SD-WAN customers must ensure that the SD-WAN site is provisioned before My Connect order submission. Only one Adaptiv My Connect order can be associated with a customer.

To submit an order

  1. Navigate to Order Management and click Create Order.
    To get help filling out individual order entry fields, please check out the Order Entry Guidelines below.

  2. On the General & Site Information page, fill out the individual installation site details and click Save & Next.

  3. On the Configuration Information page, provide the details to support the selected configuration options and click Save & Next.
    An additional section, Adaptiv SD-WAN Details, is included in the Configuration Information page to enter the CPE LAN Subnet details for SD-WAN orders.

  4. On the Link Information page, specify the details of individual underlay links and click Save & Preview.

  5. Review the order summary and click Submit order.
    Note that if the Return to order table is clicked on, the order is not submitted and remains in an Open status.

Order entry guidelines

Use the guidelines listed here to fill the order form fields.

  • General & Site Information

    Field
    Description
    • Adaptiv SD-eRouter
    • Adaptiv SD-Internet
    • Adaptiv SD-WAN
    • Adaptiv My Connect
    Select the required product.
    License Tier
    Available licenses matching the enterprise size and bandwidth requirements.
    Number of Licenses (Adaptiv My Connect)
    Enter the number of required licenses.
    Device MAC Address
    MAC Address assigned to the specific Edge device. This field is optional and users can choose to enter this information if it is known at the time of order.
    Device Serial Number
    MAC Address of the specific Edge device. This field is optional and users can choose to enter this information if it is known at the time of order.
    Adaptiv SD-WAN Node Type (For Adaptiv SD-WAN service only)
    Indicate whether the network site is a branch, data center, and/or headquarter. 
    CPE Device

    Available Adaptiv | Edge device options for selected license tier.

    SD-eRouter installation is supported only on E-40. The Portal will auto-select E-40 if the product selected is SD-eRouter. 

    Number of Required Links

    The number of Internet links to be connected to Adaptiv | Edge.

    Depending on the device and product combination selected, the Portal displays the number of links in the drop-down menu.

    Partner
    Name of the partner organization.
    Customer

    The company to whom the partner organization channels Adaptiv Networks services. 

    Partner Order #

    An order number provided by a partner to their customer.

    Customer Site Ref #
    An alphanumeric number that helps to identify multiple sites for the same customer. This value must be unique to each order of that customer. For example, a street name or street number. This value is validated against existing and canceled orders of that customer to ensure their uniqueness. 
    Site Contact Name and Site Contact Number
    Name and contact of an individual at the customer site responsible for receiving the shipment of Adaptiv | Edge and facilitating installation. 
    Alternate Contact Name, Alternate Contact Number, and Alternate Email
    An alternate contact represents any individual at the customer site to be contacted for shipping or installation purposes in case the primary contact is unavailable.
    Submitter Email
    This field is auto-populated with the email of the individual who submitted the order.
    Site Address
    Complete address of the installation site.
    Shipping Address

    Complete address of the site where Adaptiv | Edge is shipped. To ship the Edge device directly to the installation site, select the "Is shipping address as the site address?" checkbox.

    Time Zone Install
    Time zone at the installation site; useful to schedule installs if the customer is requesting installation assistance from Adaptiv Support Engineers.
    Tracking Number
    If the Edge device was shipped before provisioning, please provide a shipment tracking number here. Alternatively, you can provide this number later by editing the order details.
    Configuration Options

    Device configuration options are available for the selected product.

    To avoid lengthy install times, it is advisable to specify the configuration requirements during order entry. Note that requesting additional configurations during install increases the time for install.

    Minimum Expected Download Bandwidth (Mbps)

    Minimum Expected Upload Bandwidth (Mbps)

    Specify the expected minimum download and upload bandwidth.

  • Configuration Information

    FieldDescription
    Network DetailsFor orders with more than one public IP address, please specify the subnet mask. Additional public IP addresses are charged as an add-on to the service. 
    DHCP Server Details

    Use this section to define DHCP server configuration.

    Details

    FieldDescription
    Type
    Public – Select this option to configure an available public IP address to the device connected to the LAN port. Adaptiv Network will notify the used public IP address prior to shipping out the device.

    Private  – Select this option to configure the Edge device to act as a DHCP server. If selected, users must specify the related field values.

    DHCP Server Router IPThe IP address to be assigned to LAN interface.
    CIDRSpecify the subnet
    DHCP Start and End RangeThe first and last usable IP address within the specified subnet range
    TFTP Server NameIP address, FQDN, or URL for a TFTP server
    Primary DNS Server IP address of the Primary Domain Name Server
    Secondary DNS Server IP address of the Secondary Domain Name Server
    Voice Details 

    Specify rules to prioritize voice traffic. (SD-Internet and SD-WAN orders only)

    Details

    FieldDescription
    Codec UsedDefine codec for the voice application
    Number of Simutaneous CallsAn approximate number of calls expected simultaneously over the application at a given time.
    VoIP Port NumberDefine port for VoIP traffic
    DHCP TaggingSelect DHCP 46 from the drop-down menu.
    Automatically Reserved Bandwidth for Voice Traffic (Kbps) The system automatically calculates and displays the bandwidth that will be reserved for the VoIP call.  
    VoIP/SIP Server IP or Gateway The IP address or Gateway of the VoIP or SIP server.
    SNMP Monitoring Details

    Use Adaptiv | Edge as an SNMP agent. 

    Details

    FieldDescription
    Monitoring CommunityName of the monitoring community
    Host IPIP address of the monitory community host
    CIDRDefine monitory host subnet.
    Adaptiv SD-WAN Details 

    Provide CPE LAN subnets for the remote sites in this section. (SD-WAN orders only)

    Details

    FieldDescription
    CPE LAN Subnet for this siteEnter subnet address assigned to the LAN interface of the Edge device at site.
    CIDRSelect the required subnet mask.
    Traffic Prioritize Information

    Set rules to prioritize data traffic other than voice. (SD-Internet and SD-WAN orders only)

    Details

    FieldDescription
    Protocol NameSelect the network protocol for an application
    DirectionDirection of the data traffic to be prioritized
    SourceThe IP address and port numbers to identify source of the data traffic.
    DestinationThe IP address and port numbers to identify destination of the data traffic.
    Internet Breakout Configuration

    Set business-critical profiles for the Internet Breakout configuration. For details, see Business-Critical Profiles. To add pre-defined application templates, simply click the checkbox for that template.

    Details 

    FieldDescription
    Profile NameEnter a name for the profile. In case, a user does not enter a profile name, the Portal will automatically name a profile as Profile# where # is the number of the next profile in sequence.
    SourceSource IP address or port number of the application data.
    DestinationDestination IP address or port number of the application data.
    Protocol Select the protocol being used by the application.
    Enable ProfileBy default, this option is toggled to No. To add a profile to data prioritization, toggle to Yes.
    Additional Comments
    Use this section to convey information that otherwise cannot be provided through the order entry form. For example, request to provide additional IP addresses or request assistance for installing devices.
    Attach File (s)
    Attach documents such as a network diagram or IP justification form.
    Adaptiv My Connect

    Specify information required to provision the Adaptiv My Connect network.

    Details 

    Field
    Description
    Import Users
    Use a CSV file to provide information about multiple users. Use the template provided to upload information in the correct format.
    DNS
    Enter a comma-separated list of DNS servers and search domains for the client.
    Users & Site Access
    Enter user information manually. The site access column lists all available sites with the SD-WAN network.



  • Link Information

    Field
    Description
    Connection Type
    Specify the link type. For example - Fiber, DSL, Cable, Wireless, EoC, and so on. 
    Link Provider
    Internet Service Provider for the lin.
    Link Circuit ID
    Circuit ID of the links as provided by ISP.
    Inbound Sync Rate (Mbps)
    Provisioned inbound speed for the link.
    Outbound Sync Rate (Mbps)
    Provisioned outbound speed for the link.
    Link Type

    Specify the type of port essential to connect to individual links.

    Supported options include DHCP-Client, Static IP address, and PPPoE Authentication. 

    Back-up Link (Overlay Tunnel)
    If a site has two or more links, select this checkbox to configure a backup link for overlay tunnel.​​
    Internet Breakout

    Internet Breakout is configured, by default, on WAN1. However, users can choose which WAN port can act as primary for Internet breakout between WAN1 and WAN2 port. For details, see Internet Breakout Link.

    Primary Link

    This option is available only for SD-eRouter orders. 

    • For orders with one link, the Primary Link checkbox is, by default, selected and cannot be unselected. 
    • For orders with two links, the Primary Link checkbox, by default, is selected for WAN1. Users have an option to choose WAN2 as their primary link.

      At any given time, only one link can be selected as a primary link.

    Link Behavior

    This option is available only for SD-eRouter orders and defines how the link(s) will behave in case there is a link outage. It can be enabled only for orders with two links.

    • Fail to Backup Link – Auto-enabled and initiate a failover to the backup link if the primary link fails. By default, this configuration is set to Yes. However, if a user chooses to disable it, there is no failover.
    • Auto Recover Primary Link – By default, this configuration is enabled. It will restore the data sessions on the primary link once it is deemed as stable by the Edge device. 
      If a user opts to set it to No, recovery of the primary link becomes a manual process and must be initiated from the CPE Management tab.

Searching orders

The Order Management table lists all the orders for the partner organization. There are two ways to search for orders in the table.

  • Search orders by status – If you know the status of your order, select it from the Filter by Order Status drop-down menu. For example, you can get a list of all orders with this status by selecting the Open status. You can then select and open the required order from this list.
  • Search orders by keywords – You can search the orders by entering keywords that are unique to the order. For example, Customer Name, Partner Order #, Order ID,  or Customer Site Ref #. Alternatively, if the MAC address or Edge Device serial number for a specific order is known, enter it to search that order. For example, to get a list of orders for a customer called Customer A, type Customer A in the search box. This gets you a list of orders for that customer. 

Editing saved orders

In some cases, the partner users might need to change or update information in the already submitted orders. For example, the customer changes the shipping address or requests some additional configuration.

  1. Navigate to the Order Management tab and search the order from the Order Management table.
  2. Click in the Action column.
  3. On the VIEW ORDER DETAILS page, click Edit next to the section you want to edit.
  4. Edit the information and proceed to save the order.

TERMS OF USE   |   ANTI SPAM   |   PRIVACY POLICY   |   USER LICENSE AGREEMENT   |   PATENTS