Upgrade using the Command Line Interface
Use the following procedure to upgrade the firmware from the command line interface (CLI).
|
|
|
Before you begin, collect the following information:
| Item | Description |
| Transfer type |
|
| IP address of the destination server | The IP address of the system where the new EOS image resides. The server must be able to accept SCP v2, FTP, TFTP, or HTTPS connections. |
| Destination port | The destination port for the server where the new EOS image will reside. |
| EOS filename | The name of the new EOS image file, including the full path where it resides. |
- Access the CLI using one of the following methods:
( Refer to the Access the Command Line Interface article for more details.)
- Console port
- SSHv2 connection
- Management Interface
- ELFIQ Central CLI
- SSH to the device, go to the ena, then syst mode
- Enter eosupdate
- When the system prompts you, enter the transfer type(scp2), IP address, port number, and type the correct path to the file that should be uploaded.
- Enter one of the following:
- Y to accept the values you entered
- N to re-enter the values
- A to cancel the operation
The device connects to the remote server.
Enter the password for the server.
Note: If you are prompted to accept the SSH certificate host file during the connection, enter Y to accept the certificate; otherwise, the upgrade process is cancelled.Enter Y to confirm the upgrade or N to cancel the operation.
Enter halt to turn off the device.
Reboot the device using one of the following options:
To reboot immediately, enter reload
To reboot after a specified number of minutes, enter reload [value].
To cancel the reboot, enter reload cancel.