This page covers how a cluster running SC//HyperCore™ HyperVisor responds to disk and node failures, and the steps to take for each.
Disk Failure
As part of the intelligent monitoring systems, the SC//HyperCore system scans and assesses hard disk status reports at regular intervals on each node. Once a disk has failed and been removed, the system is completely stable and fully redundant — it is only down the capacity and I/O of that disk.
All SC//HyperCore disks are hot swappable and require no downtime to replace. See Support Levels and Hardware Replacement for replacement cost, shipping timelines, and support-tier coverage.
- Contact Scale Computing Support for a replacement disk when alerted that a disk has failed.
- Identify the disk to replace from the DISK view of the System Display Panel when you receive the replacement disk.
- Verify the node IP before replacing the disk.
- Remove the failed disk from the node slot.
- Wait 20 seconds for the bus to recognize that the disk has been removed.
- Insert the new disk firmly. The SC//HyperCore system will recognize the new disk and incorporate it into the system immediately. No rebuild process is necessary.
- Ship the failed disk back to Scale Computing using the included return label.
Node Failure
* This does not apply to Single Node Systems.
The SC//HyperCore system is designed to continue running through a single node failure. It will automatically detect the loss of availability and will intelligently restart VMs on the remaining nodes as long as there are sufficient resources.
Power Loss:
- Determine if the node is powered on or off.
- If powered off, power it back on.
- If the cause of the power loss is known, proceed with normal operation.
- If the cause is unknown, contact Scale Computing Support.
Software / Hardware Issue:
- If the node is powered on, hook a crash cart (monitor and keyboard) to the node and check if it is responsive to keyboard input.
- If unresponsive, contact Scale Computing Support.
- If responsive, review the network connections.
Networking Issue:
- Ensure all network cables for the node are firmly plugged in.
- Ensure network switches are powered on and functioning correctly.
- Ensure all VLANs and interconnects are functioning correctly.
- Determine if the node is accessible from the LAN network.
- If not reachable from the LAN network, contact Scale Computing Support.
- If accessible from the LAN network but not the backplane network, contact Scale Computing Support.