Scale Computing MG3 edge security device

The Scale Computing™ MG3 is the earlier generation of edge security device (ESD). It does the same job as the current models: it's the site's firewall and gateway, and it connects the site to SC//AcuVigil™. Many sites still run an MG3.

Revisions

Revision Tile shows
MG3 MG 002… to MG 005…
MG3v3 MG 006… to MG 008…
MG3v4 MG 009… to MG 00b…

Some applications support only some revisions. For example, a page may list "MG3 (version 3 or later)". Each application's page lists the models it supports.

Network ports

Port Use
WAN The primary internet connection.
AUX A second port that can be set up as a LAN segment or as a second internet connection.
LAN The site's local network. Devices connect through a switch attached to this port, with network segments carried as VLANs.

All three are gigabit Ethernet ports.

Status lights

LED Meaning
PWR The device has power.
CLOUD On: the ESD is reporting to SC//AcuVigil. Off: its last attempt to report failed. Blinking: the ESD couldn't set its clock from the internet.
SEC On: at least one VPN tunnel is up. Off: no VPN tunnel is up.
DIAG On while the ESD is writing its configuration to storage.
WAN, AUX, LAN One indicator for each network port.
DOOR Door sensor indicator, for sites using Door Monitoring.
TEMP Temperature sensors. Blinks slowly when one sensor is detected and faster when two or more are detected. Off when the sensors can't be read.

Door and temperature sensors

The MG3 has inputs for door contacts and temperature probes, used by the Door Monitoring and Temperature Monitoring applications.